The objective of this study was to evaluate the resistance flexural of the composite resin Filtek P60 (3M/ESPE) to being light-cure for 3 units LED and a halogen unit. The times of fotoactivación were of 20 seconds for the lamps LED and of 40 seconds for the halogen unit. The distance of the light-cure tip in all cases was of 2 mm high. The composite resin was inserted by incremental technique in a metallic mold carried out according to the specification ISO 4049, the metallic mold is approximately of 25 mm long, 2 mm high and 2 mm wide.
El objetivo de este estudio fue evaluar la resistencia flexural de la resina compuesta Filtek P60 (3M/ESPE) al ser fotocurada por 3 lámparas LED y una lámpara halógena. Los tiempos de fotoactivación fueron de 20 segundos para las lámparas LED y de 40 segundos para la lámpara halógena. La distancia de la punta de fotoactivación en todos los casos fue de 2 mm de altura. La resina compuesta fue insertada mediante técnica incremental en un molde metálico realizado según la especificación ISO 4049 en molde metálico de 25 mm de largo, 2 mm de altura y 2 mm de ancho aproximadamente.